Synchronised write (#IDENT WR SYN)
Syntax: |
#IDENT WR SYN [ AX=<axis_name> | AXNR=.. ID=<Ident_nr> VAL=.. TYP=.. DEC=.. <Drive_type> [ NO_WAIT ] ] |
AX=<axis_name> | Name of SERCOS axis |
AXNR=.. | Logical axis number of the SERCOS axis, positive integer |
ID=<Ident_nr> | ID Number in SECOS format, e.g. S-0-0047 or P-0-0129 |
VAL=.. | Value to be written; real number |
TYP=.. | Data type of value (2 or 4 byte length): 2: 2 bytes data length 4: 4 bytes data length |
DEC=.. | Number of decimal places; positive integer |
<Drive_type> | Drive type SERC: SERCOS drive (currently only one permitted) |
NO_WAIT | No waiting for successful writing of the parameter. If this keyword is not programmed, the interpolation always waits for the parameter to be written. |
Programing Example
Non-synchronised write (IDENT)
:
#IDENT WR SYN [AX=X ID S-0-0104 VAL 655.35 TYP 4 DEC 2 SERC]
#IDENT WR SYN [AXNR=1 ID S-0-0104 VAL 655.35 TYP 4 DEC 2 SERC]
:
#IDENT WR SYN [AX Y ID S-0-0104 VAL655.35 TYP 4 DEC 2 SERC NO_WAIT]
:
Attention
No plausibility check is made for logical axis number, identification number or the programmed attributes of data type and decimal places. The operator is solely responsible for making the correct entries.