Request at different times

Programing Example

prg_example

Vary the "delete distance to go” HLI signal

In the test program below, the "delete distance to go" HLI signal is triggered at different times in the NC blocks N50, N80 and N100.

%deldisttogo.nc

N010 G90 G165 G162

N020 G00 X0 Y0 Z0 F1000

N030 G01 X10 Y10

N040 $FOR P1 = 1,4,1

N050 G01 Y110  (1st “delete distance to go” signal)

N060 G01 Z30

N070 G01 X50

N080 G01 Y60 (2nd “delete distance to go” signal)

N090 G01 X100

N100 G02 X150 Y10 J-50 (3rd “delete distance to go” signal)

N110 G01 Y10

N120 G00 X10 Y10

N130 $ENDFOR

N140 M30

Delete distance to go at different times