Drive probing input for PROBE0/1 Keyword (P-AXIS-00583)

P-AXIS-00583

Number of the drive-specific probing input assigned to the keyword PROBE0 or PROBE1 in the command #MEAS[INPUT=..].

Description

This parameter defines which drive probing input is assigned to the keywords INPUT=PROBE0 and INPUT=PROBE1 in the command #MEAS.

Assign parameters to the keywords as follows:

Keyword

Parameter

'PROBE0'

kenngr.measure.probe[0].input

'PROBE1'

kenngr.measure.probe[1].input

 

Example:

When kenngr.measure.probe[0].input has the value 1, probing input 1 of the drive is used by the NC command #MEAS [AX=X INPUT=PROBE0] on receipt of the next probing command on the X axis.

The permissible value range depends on the drive type. If the parameterised value is invalid, the error message ERR-110622 is output and the value is corrected.

If no value is parameterised for this parameter, the following default values are used:

Parameter

Default value

kenngr.measure.probe[0].input

P-AXIS-00517

kenngr.measure.probe[1].input

P-AXIS-00539
(If P-AXIS-00059 has the value 0, the value of P-AXIS-00517 is used).

Parameter

kenngr.measure.probe[i].input

Data type

SGN16

Data range

----

Axis types

T, R

Dimension

T: ----

R,S: ----

Default value

0

drive types.

Simulation, Conventional, SERCOS, Terminal, Lightbus, Profidrive, CANopen