Transfer type
The values can be transferred for most drive profiles
- cyclically as process datum or
- over an acyclical parameter channel
The parameter P-AXIS-00397 defines how the transferred datum is transferred to the drive.
Possible values are:
"CYCLIC" | Transfer is cyclical in the process data |
"ACYCLIC" | Transfer is over the acyclical parameter channel |
"IGNORE" | No data is transmitted to the drive. |