ID 1599
Not enough block motion path for position controlled stop. | ||||
Description | After activation of measurement signal via measuring probe, residual path For further informations see PROG//Section: Edge bending. | |||
Response | Class | 6 | Program execution stop. | |
Solution | Class | 7 | Check whether there is sufficient residual path available in the NC program after activating the measuring probe. Increase residual path or, if possible, reduce the value of channel parameter P-CHAN-00030. | |
Parameter | %1: | Expected value [0.1 µm or 0.0001°] | ||
Current necessary braking distance. | ||||
%2: | Current value [0.1 µm or 0.0001°] | |||
Current remaining movement residual path. | ||||
Error type | 1, Error message from NC program. | |||
|