ID 11016

Same object ID already in use.

Description

One cause of error can be the generation of communication objects of V.E. variables with great arrays.

 

Extract from the V.E. List containing error that occurred

#

var[3].name                         VARIABLE_4

var[3].type                         REAL64

var[3].scope                        GLOBAL

var[3].synchronisation              TRUE

var[3].array_size                   3000

var[3].access_rights                READ_WRITE

Error case

var[3].create_hmi_interface         TRUE

Correction

var[3].create_hmi_interface         FALSE

 

Alternatively, the number of communication objects declared in the V.E. list may be too big.

Response

Class

3

Abort job processing

Solution

Class

7

Reduce number of required communication objects

Parameter

%1:

Current value [-]

Concerning ID Nr.

%2:

Error value [-]

Name of the concerning object

%3:

Current value [-]

Name oft he object with the existing object ID

Error type

-