ID 13307

Feed velocity is not defined or incorrect.

Description

No or an invalid feed velocity (>=0) for machining or infeed is defined. No feed velocity was programmed in the main program either.

Response

Class

-

Error: Transition to error state. Complete reset of the NC channel necessary.

Solution

Class

-

Check parameter setting and correct input parameters for the feed velocity.

Error type

1, Error message from NC program.