ID 13407

Measuring distance in 3rd main axis is not defined @P6.

Description

No measuring distance was defined in the 3rd main axis, or the value is 0.

Response

Class

-

Error: Transition to error state. Complete reset of the NC channel necessary.

Solution

Class

-

Define the measuring distance at cycle call with parameter @P6.

Error type

1, Error message from the NC program