ID 14042

Invalid String in V.G.VOLCOMP[@P1].FILE[@P2] for Volumetric Compensation for logging/file archiving.

Description

The string for the path and name of logging and compensation files is not permitted. The files cannot be written or archived.

Response

Class

-

Error: Transition to error state. Complete reset of the NC channel necessary.

Solution

Class

-

Check and correct the transferred file paths and names.

Error type

1, Error message from NC program.