ID 20035

Difference between programmed and calculated centre point too big. centre point from calculated point too large.

Description

With active centre point correction (G165) based on the programmed centre point coordinates I, J, K, a centre point is calculated. This error message is generated if this calculated centre point deviates too much from the programmed centre point (P-CHAN-00059).

Example:

Wrong:

N10   G00 X0 Y0 Z0

N20   G02 X10 I7 F1000

N1000 M30

Correct:

N10   G00 X0 Y0 Z0

N20   G02 X10 I5 F1000

N1000 M30

Response

Class

2

Abort NC program processing.

Solution

Class

3

Adjust centre coordinates. Check in which measuring system (absolute/relative) the centre point is programmed (G161/G162). Possibly complete missing centre point coordinates.

Parameter

%1:

Current value [0.1 µm or 0.0001°]

 

%2:

Limit value [0.1 µm or 0.0001°]

 

Error type

1, Error message from NC program.