ID 20050

Old measured value is still considered.

Description

During a measurement run, the offset from the last measurement run is still improperly enabled. Important: Please be aware, that before any measuring movement deactivating the existing offset using G102 is as well mandatory as making sure, that the measurement probe is reached during the movement!

Example:

Wrong:

N5  X0  

N10 G100 X20 F1000

N20 G101 X1

N30 G100 X10

N40 G101 X1

M30

Correct:

N5  X0  

N10 G100 X20 F1000

N20 G101 X1

N22 G1   X0.4711 F1000

N25 G102 X1

N30 G100 X10 F1000

N40 G101 X1

M30

Response

Class

2

Abort NC program processing..

Solution

Class

3

Check and modify NC program. Before selection of measuring cycle deselection of old measuring offset via G102.

Parameter

%1:

Logical axis number [-]

 

Error type

1, Error message from NC program.