Face turning axis is used twice in processing plane.

Description

Only one axis, the first or the second main axis, can be used as face turning axis. In this case, however, both axes have the property of a facing axis (P-AXIS-00015).

Response

Class

2

Abort NC program processing.

Solution

Class

3

Check and modify the axes parameter settings. Only one of the main axes may be facing axis P-AXIS-00015.

Parameter

%1:

Logical axis number [-]

 

Error type

-