ID 20126

Double-programmed TRC selection mode.

Description

In the same NC block, more than one G function has been programmed from the group of TRC selection modes.

Example:

Wrong:

N10   G00 X0 Y0 Z0

N20   G138 G41 G139

:

N1000 M30

 

Exceptions:

Programming G05 in combination with another TRC selection type is permissible.

Response

Class

2

Abort NC program processing.

Solution

Class

3

Check and modify NC program. Remove the inadmissible G function.

Parameter

%1:

Error value [-]

Number of inadmissible programmed second G function

Error type

1, Error message from NC program.