ID 20418

Channel parameters: Number of spindles and number of configured spindle axes do not match.

Description

During start-up, the channel parameter check determines that the actual number of configured spindles (spindle data) does not correspond to the total number of spindles P-CHAN-00082.

Response

Class

1

Start-up of the control is continued.

Solution

Class

1

During start-up in case of conflict the total number of spindles is set to the real number of configured spindles and the start-up is continued.

Parameter

%1:

Current value [-]

Total number of spindles P-CHAN-00082

%2:

Expected value [-]

Real number of configured spindles (spindle data)

%3:

Corrected value [-]

Automatically corrected total number of spindles

Error type

2, Error message by data transfer from parameter list into control device.