Channel parameters: Incorrect setting of number of groups. | ||||
Description | During start-up, the channel parameter check determines that the actual number of configured axis groups does not correspond to the specified total number of axis groups P-CHAN-00023. | |||
Response | Class | 1 | Start-up of the control is continued. | |
Solution | Class | 1 | During start-up in case of conflict the total number of axes groups is set to the smaller number of both values and the start-up is continued. Note: Possibly not the complete number of configured axes groups of the channel parameter list is available after start-up in the channel! At the moment in NC channel only one axes group (index 0) is permissible. | |
Parameter | %1: | Current value [-] | ||
Real number of configured axes groups | ||||
%2: | Expected value [-] | |||
Total number of axis groups P-CHAN-00023 | ||||
%3: | Corrected value [-] | |||
Automatically corrected total number of axes groups | ||||