ID 20487

Manual mode parameter is out of data format.

Description

One of the manual operation parameters (increment or speed) programmed with the NC commands #JOG CONT[...], JOG INCR[...] or #SET TIP[...] or #SET JOG[.[...].] is out of value range.

For further information see:

  • [PROG// Section: Handwheel operating mode]
  • [PROG// Section: Incremental jog operating mode]

Response

Class

2

Abort NC program processing.

Solution

Class

3

Check and modify NC program. Program a permissible value for the step widths or feed rates.

Parameter

%1:

Error value [-]

Step width or feed rate

%2:

Lower limit value [-]

 

%3:

Upper limit value [-]

 

Error type

1, Error message from NC program.