ID 20582

Value following G159 is out of data format.

Description

The numerical value programmed with G159=<expr> (zero offset group) is outside the permitted value range.

[PROG//Section: Extended zero offset (G159)]

Response

Class

2

Abort NC program processing.

Solution

Class

3

Check and modify NC program. Program a zero offset group with a valid value.

Parameter

%1:

Error value [-]

 

%2:

Lower limit value [-]

 

%3:

Upper limit value [-]

 

Error type

1, Error message from NC program.