ID 20707

Program pathes of the same type are not allowed to have the same priority.

Description

In the start-up list, program paths that may be of the same type as P-STUP-00020 but may not have the same priority as P-STUP-00021 are configured .

 

Example with error:

pfad[0].prg[0]          v:\ref_test\nc_prg\init

pfad[0].log_nr[0]       1

pfad[0].typ[0]          0x03

pfad[0].prioritaet[0]   1

#

pfad[0].prg[1]          v:\ref_test\nc_prg\dec

pfad[0].log_nr[1]       1

pfad[0].typ[1]          0x03

pfad[0].prioritaet[1]   1

Response

Class

2

Start-up of the control is aborted.

Solution

Class

6

Check and modify the priority settings for the program path in the start-up list. Repeat the NC start-up.

Parameter

%1:

Error value [-]

Invalid priority P-STUP-00021

%2:

Current value [-]

Program path type P-STUP-00020

Error type

-