Channel parameters: Process time has to be 0 for synchronization mode MOS.

Description

During start-up, the check of the channel parameters determines that, for technology functions (M, H, S, T) defined with synchronization mode MOS (see P-CHAN-00041), the assigned process times are set to a value unequal to zero (nil) (see e.g. P-CHAN-00040).

Response

Class

1

Start-up of the control is continued.

Solution

Class

1

During start-up in case of conflict the process time is set to 0 and the start-up is continued.

Parameter

%1:

Current value [-]

Index of the invalid technology function (M, H, S, T)

%2:

Error value [-]

Invalid process time

%3:

Corrected value [-]

Automatically corrected process time

Error type

2, Error message by data transfer from parameter list into control device.