ID 20819
Channel parameters: G- or M-function is not permitted as default value. | ||||
Description | A defined default value for G functions (P-CHAN-00063) or M functions (P-CHAN-00064) in the channel parameter list is out of the permissible range of data. | |||
Response | Class | 1 | Start-up of the control is continued. | |
Solution | Class | 1 | In the channel parameters, the default value of the corresponding G or M function must be checked and changed before the next controller start-up. During start-up in case of conflict the invalid entry is set to a permitted value of the function. | |
Parameter | %1: | Error value [-] | ||
| ||||
%2: | Corrected value [-] | |||
| ||||
%3: | Current value [-] | |||
Group number of the invalid default entry | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|