ID 20889
Channel parameters: Face-ID is out of range of permissible values. | ||||
Description | During start-up, the entry for the facing ID is checked for the valid value range. The value of the Face-ID P-CHAN-00008 in the channel parameters list is out of range. | |||
Response | Class | 1 | Start-up of the control is continued. | |
Solution | Class | 1 | Check and modify the value of the Face-ID P-CHAN-00008 in the channel parameters before the next controller start-up. During start-up in case of conflict the value of Face-ID is set to the maximum limit. | |
Parameter | %1: | Error value [-] | ||
Invalid value of Face-ID in channel parameter list | ||||
%2: | Upper limit value [-] | |||
Maximal value of Face-ID | ||||
%3: | Corrected value [-] | |||
Automatically corrected value of Face ID | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|