ID 21120

Double programming of counter parameter.

Description

The count parameter (COUNT) is programmed several times in the #SIGNAL command for sending signals.

Response

Class

2

Abort NC program processing.

Solution

Class

3

Check the signal command and remove the redundant COUNT.

Error type

1, Error message from NC program.