ID 21196

Scope of validity (channel / global) of external variable not configured.

Description

In the external variable list an invalid identification is entered for the scope of validity (element scope).

Response

Class

2

Start-up of the control is continued. The incorrect identifier is implicitly replaced by the identifier VE_CHANNEL. Also the external address of this variable is calculated, but not checked for plausibility.

Solution

Class

7

Initialize the external variable correctly in the list [EXTV].

Parameter

%1:

Error value[-]

Value of the incorrect identification.

%2:

Corrected value [-]

Value of the corrected identification (VE_CHANNEL).

%3:

Corrected value[-]

Corrected address of the external variable.

%4:

Current value[-]

Index of the incorrect, but corrected external variable.

Error type

-