ID 21203

Channel parameters: Synchronization mode MET_SVS needs pre output time greater than or equal to NC-cycle time of control.

Description

During start-up for M-/H-functions with the synchronisation mode MET_SVS, the check of the assigned pre output time P-CHAN-00070 / P-CHAN-00107 detects that these time is smaller than the cycle time.

Response

Class

1

Start-up of the control is continued.

Solution

Class

1

In the channel parameters, check and modify the pre-output time P-CHAN-00070 / P-CHAN-00107 before the next controller start-up for the corresponding M/H function. During start-up in case of conflict the pre output time is set to cycle time and the start-up is continued.

Parameter

%1:

Current value

Number of the M-/H-function

Note:

For M-functions multiple ID 1 is valid.

For H-functions multiple ID 2 is valid.

%2:

Error value[-]

Incorrect pre output time.

%3:

Corrected value [-]

Automatically corrected pre output time (= cycle time)

Error type

2, Error message by data transfer from parameter list into control device.