ID 21391

Invalid tool type for OTC operation.

Description

When selecting the OTC function (Online Tool Compensation), it must be ensured that the tool used is a grinding tool. That's why the tool type, entered in the tool data is checked.

The error message is output if the active tool is not a grinding tool, i.e. the corresponding parameter P-TOOL-00001 is not correctly assigned in the tool data.

Response

Class

2

Abort NC program processing.

Solution

Class

3

Enter tool tool type 2 for grinding tool (P-TOOL-00001) in the corresponding tool data, update lists and restart NC program.

Parameter

%1:

Error value [-]

Current entered tool type

%2:

Expected value [-]

Tool type for grinding tools

Error type

1, Error message from NC program.