ID 21404

Channel parameters: Multiple axes programming without active "multi_dimension_in_block" is not useful.

Description

During start-up, the channel parameter check determines that it only makes sense to set P-CHAN-00148 to 1 if P-CHAN-00116 is also set to 1.

Response

Class

1

Start-up of the control is continued.

Solution

Class

1

During start-up in case of conflict the multiple axes programming is set to 0 (FALSE) and the start-up is continued.

Before the next start-up, set the channel parameters P-CHAN-00116 and P-CHAN-00148 correctly:

P-CHAN-00116

P-CHAN-00148

Check result

0

0

OK

1

0

OK

1

1

OK

0

1

NOT OK

Parameter

%1:

Error value [-]

Channel parameter P-CHAN-00148 incorrectly assigned

%2:

Corrected value [-]

 

Error type