ID 21408
#GET WCS POSLIMIT not allowed during active synchronous operation. | |||
Description | During active synchronous operation (#ENABLE AX LINK or #AX LINK ON) the command #GET WCS POSLIMIT is programmed in the NC program. This is not permitted. Example: Wrong: N10 G00 X0 Y0 Z0 N30 #SET AX LINK[1, B=X] N40 #ENABLE AX LINK[1] : N100 #GET WCS POSLIMIT [VC1=1 VC2=0 VC3=0] : N1000 M30 Correct: N10 G00 X0 Y0 Z0 N30 #SET AX LINK[1, B=X] N40 #ENABLE AX LINK[1] : N90 #DISABLE AX LINK[1] N100 #GET WCS POSLIMIT [VC1=1 VC2=0 VC3=0] : N1000 M30 | ||
Response | Class | 2 | Abort NC program processing. |
Solution | Class | 3 | Check and modify NC program. Deselect the active synchronous operation with #DISABLE AX LINK or #AX LINK OFF (ALL) before the use of the command #GET WCS POSLIMIT. |
Error type | 1, Error message from NC program. | ||
|