ID 21452

Invalid UNIT value programmed.

Description

The tool unit (UNIT) programmed in the NC command #TOOL DEF [...] can no longer be stored in the internal working data.

Response

Class

2

Abort NC program processing.

Solution

Class

3

Check and modify NC program. Reduce the number of tool units defined or if possible replace redundant tool units with new unit definitions.

Parameter

%1:

Error value [-]

ID number of the programmed UNIT

%2:

Lower limit value [-]

Maximum number of permissible UNIT definitions

%3:

Upper limit value [-]

 

Error type

1, Error message from NC program.