ID 21538

Channel parameters: Table of path dependent dynamic weightings contains an active row with invalid parameter value.

Description

During start-up, the channel parameter check determines that the table of dynamic weights P-CHAN-00191 - P-CHAN-00194 contains an impermissible minimum limit value. The smallest permissible limit value is 1% (10 per mille).

Response

Class

1

Start-up of the control is continued.

Solution

Class

1

In the event of a conflict, P-CHAN-00191 - P-CHAN-00194 is assigned a default value during the start-up, and the start-up is continued.

Parameter

%1:

Current value [-]

Table index (row) with the invalid value

%2:

Error value [0.1%]

Weighting factor for rapid feed velocity

%3:

Error value [0.1%]

Weighting factor for rapid feed acceleration

%4:

Error value [0.1%]

Weighting factor for rapid feed ramp time

%5:

Corrected value [0.1%]

Value of the corrected weighting factor

Error type