ID 21543

Tool dynamic data for PLC spindle not effective.

Description

The assigned spindle is configured in the channel parameters as a spindle controlled directly by the PLC (P-CHAN-00069). But for this kind of spindles no tool specific dynamic data can be assigned.

Response

Class

2

Abort NC program processing.

Solution

Class

3

Check spindle configuration and modify it if necessary. Either the spindle must be created as a controlled spindle in the channel (see P-CHAN-00069) or the spindle assignment of the dynamic data must be removed in the tool data (P-TOOL-00012).

Parameter

%1:

Error value [-]

ID of tool parameter

%2:

Error value [-]

Value of tool parameter

%3:

Expected value [-]

Correct value of tool parameter

%4:

Current value [-]

Tool number

%5:

Current value [-]

ID of channel parameter with value

Error type

1, Error message from NC program.