ID 21578

Double programming of H-function by tube profile parameter.

Description

The parameter setting of active function tube profile machining #CYL[] contains double setting of M/H number.

Assignment in section h_synch[<H-Number>] or m_synch[<M-Number>] and tube_profile.techno_nr_rnd_on, tube_profile.techno_nr_rnd_off.

Invalid parameter setting leads to deactivation of specific M/H-Code output for #CYL[] function.

Response

Class

1

Start-up of the control is continued.

Solution

Class

1

Check and correct parameter settings of channel machine data in

tube_profile.techno_nr_rnd_on, tube_profile.techno_nr_rnd_off.

Parameter

%1:

Error value [-]

Current M/H number with double setting from h_synch[] or m_synch[]

%2:

Corrected value [-]

Assigned M/H value off

tube_profile.techno_nr_rnd_on, tube_profile.techno_nr_rnd_off

%3:

 

Corrected value off

tube_profile.techno_nr_rnd_on, tube_profile.techno_nr_rnd_off

Error type

2, Error message by data transfer from parameter list into control device.