ID 21579

Invalid setting of H-function by tube profile parameter.

Description

The parameter setting of active function tube profile machining #CYL[] contains invalid setting of M/H code number. Either the M/H code exceeds maximum permissible value or an internal locked M-code number was used (e.g. M30 program end mark).

Invalid parameter setting leads to deactivation of specific M/H-Code output.

Response

Class

1

Abort NC program processing.

Solution

Class

1

Check and correct parameter settings of channel machine data

tube_profile.techno_nr_rnd_on, tube_profile.techno_nr_rnd_off

Parameter

%1:

Current value [-]

Current invalid M/H number

%2:

Limit value [-]

Maximum permissible M/H code number

%3:

Corrected value [-]

Corrected M/H-code number

Error type

2, Error message by data transfer from parameter list into control device.