ID 21579

Invalid setting of H function by tube profile parameter.

Description

The parameter setting of the tube profile processing #CYL[] function in the machine data record contains incorrect M/H code numbers. Either the M/H code exceeds maximum permissible value or an internally assigned M code number was used (e.g. M30 -> program end code).

Invalid parameter setting leads to deactivation of specific M/H code output.

Response

Class

1

Abort NC program processing.

Solution

Class

1

Check and correct parameter settings of channel machine data

tube_profile.techno_nr_rnd_on, tube_profile.techno_nr_rnd_off

Parameter

%1:

Current value [-]

Current invalid M/H number

%2:

Limit value [-]

Maximum permissible M/H code number

%3:

Corrected value [-]

Corrected M/H code number

Error type

2, Error message by data transfer from parameter list into control device.