ID 21579
Invalid setting of H-function by tube profile parameter. | ||||
Description | The parameter setting of active function tube profile machining #CYL[] contains invalid setting of M/H code number. Either the M/H code exceeds maximum permissible value or an internal locked M-code number was used (e.g. M30 program end mark). Invalid parameter setting leads to deactivation of specific M/H-Code output. | |||
Response | Class | 1 | Abort NC program processing. | |
Solution | Class | 1 | Check and correct parameter settings of channel machine data tube_profile.techno_nr_rnd_on, tube_profile.techno_nr_rnd_off | |
Parameter | %1: | Current value [-] | ||
Current invalid M/H number | ||||
%2: | Limit value [-] | |||
Maximum permissible M/H code number | ||||
%3: | Corrected value [-] | |||
Corrected M/H-code number | ||||
Error type | 2, Error message by data transfer from parameter list into control device. | |||
|