ID 21702

Number of programmed axis specific polynomials not allowed.

Description

Too many axis-specific polynomials were programmed.

Response

Class

2

Abort NC program processing.

Solution

Class

3

Reduce the number of programmed axis-specific polynomials in the NC block to match the limit value. If necessary, split programmed polynomials into several NC blocks.

Parameter

%1:

Error value [-]

The number of axis-specific programmed polynomials.

%2:

Limit value [-]

The maximum number of possible axis-specific polynomials.

Error type

1, Error message from NC program..