ID 21844

Start address and byte offset/index cannot be specified at the same time.

Description

When the external variable is created, the CNC normally assigns the start addresses automatically. However, the start address can also be specified explicitly by specifying a byte offset (see P-EXTV-00002) or the 24-byte index or by the variable name of a preceding variable (see P-EXTV-00048). However, only one of these two address methods may be used at the same time.

Response

Class

2

Current start address default in P-EXTV-00048 is deleted

Solution

Class

3

Check the start address specified for the external variable, see P-EXTV-00002, P-EXTV-00048

Parameter

%1:

Current value [-]

Name of the variable affected P-EXTV-00001

%2:

Current value [-]

Index var[i] of the variable affected in the configuration file

%3:

Current value [-]

Byte offset P-EXTV-00002 or 24-byte index of the variable

%4:

Error value [-]

Start address of the variable via variable name P-EXTV-00048

%5:

Corrected value [-]

Corrected value for the start address P-EXTV-00048

Error type

-