ID 44032
FB error: MCV_ForceJobAck: For this purpose the value assigned to that input should be > 0. | |||
Description | The function block should check if the acknowledge interface is occupied by one and the same response of a job for a number of PLC cycles in which the number of cycles is assigned to the function blocks input "NrChkCycles". The function block requires a value > 0 at input "NrChkCycles" for this purpose. But in case the error is displayed the value is 0. | ||
Response | Class | - | The error is displayed and in the following PLC cycle the output "JobBlocks" is set TRUE. |
Solution | Class | - | Assign a value > 0 to input "NrChkCycles". |
Error type | - | ||