Programmed revolution feed rate too small.
|
Description
| With turning function feedrate per revolution (G95), the programmed feedrate must be greater than a minimum value.
For more information on turning functions see [PROG// Section: Turning functions].
|
Response
| Class
| 4
| Movement stop.
|
Solution
| Class
| 6
| Programming of revolutional feed > 0.
|
Parameter
| %1:
| Current value [µm / revolution]
|
Current programmed feedrate per revolution.
|
%2:
| Lower limit value
|
Lower limit for revolutional feed.
|
Error type
| 1, Error message from NC program.
|
|