ID 50181

Programmed revolution feed rate too small.

Description

With turning function feedrate per revolution (G95), the programmed feedrate must be greater than a minimum value.

For more information on turning functions see [PROG// Section: Turning functions].

Response

Class

4

Movement stop.

Solution

Class

6

Programming of revolutional feed > 0.

Parameter

%1:

Current value [µm / revolution]

Current programmed feedrate per revolution.

%2:

Lower limit value

Lower limit for revolutional feed.

Error type

1, Error message from NC program.