ID 50498
The available motion path is less than the defined residual distance. | ||||
Description | With the Edge banding function,the residual path P-CHAN-00030 in the channel parameter list is reduced after the measurement signal is activated by the measuring probe. The block motion path available at this time must be greater than P-CHAN-00030. For more information on edge banding, see [PROG// Section: Edge banding (G108)]. | |||
Response | Class | 4 | Movement stop. | |
Solution | Class | 0 | Either reduce P-CHAN-00030 or increase the programmed block motion path so that a residual path of at least P-CHAN-00030 is available after the response of the measurement signal. | |
Parameter | %1: | Current value [0.1 µm or 0.0001°] | ||
Residual path available in the programmed measuring block. | ||||
%2: | Expected value [0.1 µm or 0.0001°] | |||
Residual path depending on P-CHAN-00030 | ||||
%3: | Current value [0.1 µm or 0.0001°] | |||
Path distance of measurement actual positions and target positions. | ||||
%4: | Current value [0.1 µm or 0.0001°] | |||
Motion path in current motion block. | ||||
Error type | 1, Error message from NC program. | |||
|