ID 50500

Maximum permissible number of PLC spindle couplings exceeded.

Description

The number of PLC spindles active and coupled simultaneously in synchronous mode is limited (#SET AX LINK[], #ENABLE AX LINK[]).

Further information to synchronous mode see [PROG// Section: Synchronous mode].

Response

Class

6

Movement stop.

Solution

Class

6

Check parameterization of synchronous operating axes in channel machine data (P-CHAN-00037, P-CHAN-00038) or reduce number of spindle couplings in #SET AX LINK command.

Parameter

%1:

Limit value [-]

Maximum number of links of PLC spindles.

%2:

Current value [-]

Current defined number of PLC spindle couplings.

%3:

Logical axis number [-]

Logical axis number (P-AXIS-00016) of the master spindle axis affected.

%4:

Logical axis number [-]

Logical axis number (@@P-AXIS-00016) of slave axis coupled to the master axis and which leads to exceeding of maximum coupling number.

Error type

1, Error message from NC program.