ID 50529

Incorrect parameter setting for measurement run to fixed stop.

Description

In conjunction with the measurement function G100, several measurement types are available. These types can be selected via the MDS or the CNC program.

An impermissible parameter setting is active during a measurement run to fixed stop.

For detailed information on G100, see

Response

Class

4

Movement stop.

Solution

Class

6

Change measurement type or parameter value 2

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis

%2:

Current value [-]

Name of machine data record parameter

%3:

Current value [-]

Machine parameter value

%4:

Current value [-]

Selected measurement type

%5:

Current value [-]

Measurement axes with motion

Error type

1, Error message from NC program..