ID 50541

Maximal permissible discrete infeed exceeds limit.

Description

The discrete infeed of an axis via PLC exceeds the permitted value range.

The maximum infeed is defined via parameter P-TOOL-00031.

Response

Class

1

Infeed is limited.

Solution

Class

1

Reduction of the discrete infeed of the axis via the PLC.

Parameter

%1:

Logical axis number [0.1 µm or 0.0001°]

 

%2:

Error value [0.1 µm or 0.0001°]

 

%3:

Lower limit value [0.1 µm or 0.0001°]

 

%4:

Upper limit value [0.1 µm or 0.0001°]

 

%5:

Corrected value [0.1 µm or 0.0001°]

 

Error type

1, Error message from NC program.