ID 50706

End of movement range reached, measuring not executed.

Description

No measurement signal was enabled in one or more axes with measurement function G100 and the option of automated motion path limiting during measurement run (see P-CHAN-00268). The movement stops before reaching the movement range limits defined by the soft limit switch.

For detailed information on measurement function G100, see [FCT-C4],

[PROG// Section: Measuring functions].

Response

Class

6

Movement stop.

Solution

Class

6

Check measuring signal of the measurement axis/axes affected.

Set measurement signal in all measurement axes with measurement interrupt.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of an affected measurement axis.

Error type

1, Error message from NC program.