ID 50787
Plane change in work or protection area definition not permitted. | ||||
Description | The machining plane may not be changed during the definition of a work or protection area (see [FCT-C14// Definition of work and protection areas]).
Example with error: #CONTROL AREA START [ID1 PROT CIRC MIN_EXCUR=-50 MAX_EXCUR=50] G01 Y100 Z100 F1000 G19 G02 G162 Y100 Z100 J-100 F1000 #CONTROL AREA END
Corrected example: G19 #CONTROL AREA START [ID1 PROT CIRC MIN_EXCUR=-50 MAX_EXCUR=50] G01 Y100 Z100 F1000 G02 G162 Y100 Z100 J-100 F1000 #CONTROL AREA END | |||
Response | Class | 6 | Movement stop. | |
Solution | Class | 6 | Check and modify the NC program | |
Parameter | %1: | Identification number [-] | ||
Identifier of affected work or protection area | ||||
Error type | 1, Error message from NC program. | |||
|