ID 50822

#EXTEND ON: No interface for programmed channel number.

Description

In order to activate the ORBIT channel, there must be an interface between the DR and ORBIT channels. This interface is opened by the DR channel with the command
#CHANNEL INTERFACE ON [EXTEND …] and coupled by the ORBIT channel with the command #TRACK CHAN ON [EXTEND = "DR channel number” …].

 

The specified "DR channel number" does not match the DR channel or no interface was opened in the DR channel with #CHANNEL INTERFACE ON [EXTEND …].

Response

Class

6

Movement stop.

Solution

Class

7

Program #CHANNEL INTERFACE ON [EXTEND …] in the DR channel before #TRACK CHAN ON [EXTEND= "DR channel number" …] in the ORBIT channel
or enter the correct specification of the channel number in #TRACK CHAN ON [EXTEND= "DR channel number" …]

Error type

1, Error message from NC program.