ID 50841

Could not determine actual edge joint.

Description

Could not determine the actual edge joint.

Possible reasons are:

  • The range between #MEAS RECORD BEGIN and #MEAS RECORD END was selected too small. More motion blocks can be placed in this range by reprogramming these two commands.
  • The touch probe geometry was incorrectly configured in the #MEAS command.

Response

Class

4

Could not determine the measurement difference between command edge and actual edge.

Solution

Class

6

Increase the #MEAS RECORD range; check touch probe configuration

Parameter

%1:

Current value [0.1 µm or 0.0001°]

Roll radius

%2:

Current value [0.1 µm or 0.0001°]

Touch probe length

%3:

Current value [0.1 µm or 0.0001°]

Measurement value X

%4:

Current value [0.1 µm or 0.0001°]

Measurement value Y

%5:

Current value [0.1 µm or 0.0001°]

Number of blocks available.

Error type

1, Error message from NC program..