ID 60139
Timeout from spindle at PLC reset. | ||||
Description | The PLC has the possibility of fetching information about a CNC reset via the HLI element .
The process response is as follows: If the PLC sets the signal enable_w in the ipo_lc_control.plc_reset control unit, the NC kernel sets the signal command_r when there is a reset. As soon as the PLC completes its own reset actions, it must set the state_wr signal to indicate that the PLC reset is completed. If the signal X_State is not set within 20 seconds the error message is issued. | |||
Response | Class | 6 | CNC-channel changes into error state. | |
Solution | Class | 6 | Clear the cause for the delayed PLC-acknowledgement and do another CNC-reset. | |
Parameter | %1: | Logical axis number [-] | ||
Logical axis number (P-AXIS-00016) of the spindle | ||||
Error type | - - | |||
|