ID 60189
Acceleration ramp 1 is greater than a_max. | ||||
Description | A movement was commissioned in which acceleration level 1 is greater than the maximum permissible axis acceleration P-AXIS-00008. The acceleration ramp 1 value is automatically corrected to P-AXIS-00008 . The cause for this warning is indicated by the parameters 4 and 5 of this warning: If parameter 4 equals 1, the movement was commissioned by the PLC and the invalid value was transferred during the commissioning. Otherwise either P-AXIS-00011 or P-AXIS-00005 is greater than P-AXIS-00008. Parameter 5 indicates which of the two values is incorrect. | |||
Response | Class | 1 | Warning output, value is corrected to P-AXIS-00008. | |
Solution | Class | 1 | Change erroneous value in axis parameter list or when commanding via HLI. | |
Parameter | %1: |
| ||
Logical axis number (P-AXIS-00016) of the spindle | ||||
%2: |
| |||
Current value. | ||||
%3: |
| |||
Corrected value | ||||
%4: |
| |||
This value indicates if the erroneous value is passed over via the HLI. 1: The value was transferred via the HLI when the order was placed. 0: The invalid value comes from a parameter list. Parameter 5 of the error message indicates the erroneous value. | ||||
%5: |
| |||
If parameter 4 is zero (nil), this value indicates which parameter triggered the warning: 0: P-AXIS-00011 is faulty. 1: P-AXIS-00005 is faulty. | ||||
Error type | 1, Error message from NC program. | |||
|