ID 60195

Deceleration ramp 2 is greater than a_max.

Description

A movement was commissioned in which deceleration stage 2 is greater than the maximum permissible axis acceleration P-AXIS-00008. The acceleration ramp 1 value is automatically corrected to P-AXIS-00008 .

The cause for this warning is indicated by the parameters 4 and 5 of this warning:

If parameter 4 equals 1, the movement was commissioned by the PLC and the invalid value was transferred during the commissioning.

Otherwise either P-AXIS-00281 or P-AXIS-00283 are greater than the maximum allowable axis acceleration P-AXIS-00008.

Parameter 5 indicates which of the two values is incorrect.

Response

Class

1

Warning output, value is corrected to P-AXIS-00008.

Solution

Class

1

Change erroneous value in axis parameter list or when commanding via HLI.

Parameter

%1:

 

Logical axis number (P-AXIS-00016) of the spindle

%2:

Current value [mm/s^2 bzw. °/s^2]

 

%3:

Corrected value [mm/s^2 bzw. °/s^2]

 

%4:

Current value[-]

 

%5:

Current value[-]

Logical axis number (P-AXIS-00016) of the spindle

Error type

1, Error message from NC program.