ID 60195
Deceleration ramp 2 is greater than a_max. | ||||
Description | A movement was commissioned in which deceleration stage 2 is greater than the maximum permissible axis acceleration P-AXIS-00008. The acceleration ramp 1 value is automatically corrected to P-AXIS-00008 . The cause for this warning is indicated by the parameters 4 and 5 of this warning: If parameter 4 equals 1, the movement was commissioned by the PLC and the invalid value was transferred during the commissioning. Otherwise either P-AXIS-00281 or P-AXIS-00283 are greater than the maximum allowable axis acceleration P-AXIS-00008. Parameter 5 indicates which of the two values is incorrect. | |||
Response | Class | 1 | Warning output, value is corrected to P-AXIS-00008. | |
Solution | Class | 1 | Change erroneous value in axis parameter list or when commanding via HLI. | |
Parameter | %1: |
| ||
Logical axis number (P-AXIS-00016) of the spindle | ||||
%2: | Current value [mm/s^2 bzw. °/s^2] | |||
| ||||
%3: | Corrected value [mm/s^2 bzw. °/s^2] | |||
| ||||
%4: | Current value[-] | |||
| ||||
%5: | Current value[-] | |||
Logical axis number (P-AXIS-00016) of the spindle | ||||
Error type | 1, Error message from NC program. | |||
|