ID 60197

Automatic calculation of coupling factor not possible.

Description

When activating the spindle interpolator coupling with automatic calculation of the coupling factor (NC command S[FEED_LINK ON ..]), the current path velocity is less than 1*10-12 um/s.

See also [PROG// Section: Spindle feed link (FEED_LINK)]

This may be caused by the path feed programmed in the NC program or by setting an override/feedhold via the HLI.

Response

Class

6

Program abort.

Solution

Class

6

Override or change program; at the time of activation of the spindle-path coupling, the path velocity must be higher.

Parameter

%1:

 

Logical axis number (P-AXIS-00016) of the spindle

%2:

Current value [1µm/s or 0.001°/s]

Current path velocity.

%3:

Limit value [1µm/s or 0.001°/s]

Permissible minimum value.

Error type

1, Error message from NC program.