ID 60197

Automatic calculation of the coupling factor not possible.

Description

When activating spindle interpolator coupling with automatic calculation of the coupling factor (NC-command S[FEED_LINK ON ..]), the current path velocity is less than 1*10-12 um/s.

See also [[PROG// Section: Spindle feed link (FEED_LINK)]]

This can be caused by the path feed programmed in the NC-program or by setting an override/feedhold via the HLI.

Response

Class

6

Program execution stop.

Solution

Class

6

Override or change program; at the time of activation of the spindle-path coupling, the path velocity must be higher.

Parameter

%1:

 

Logical axis number (P-AXIS-00016) of the spindle

%2:

Current value [1µm/s or 0.001°/s]

Current path velocity.

%3:

Limit value [1µm/s or 0.001°/s]

Permissible minimum value.

Error type

1, Error message from NC program.