ID 60198

Spindle speed too small for auto. link factor calculation.

Description

When activating spindle-path coupling with automatic calculation of the coupling factor (NC-command S[FEED_LINK ON..]), the current spindle speed is less than 1*10-12 um/s.

See also [[PROG// Section: Spindle feed link (FEED_LINK)]

This can be caused by the spindle speed programmed in the NC program or by an override /feedhold via the HLI.

Response

Class

6

Program execution stop.

Solution

Class

6

Check override or change program; at the time of activation of the spindle-path coupling, the spindle speed must be higher.

Parameter

%1:

 

Logical axis number (P-AXIS-00016) of the spindle

%2:

Current value [1µm/s or 0.001°/s]

Current spindle speed.

%3:

Limit value [1µm/s or 0.001°/s]

Permissible minimum value.

Error type

1, Error message from NC program.