ID 60274

Timeout: Axis filter not within tolerance window.

Description

During reset, axis position request or Exact stop , the CNC waits for the axis filter to reach the tolerance window P-AXIS-00351. If this is not the case within a certain period of time (e.g. due to a strongly oscillating filter), the axis filters for the affected axis are temporarily switched off. They are reactivated after a CNC-reset.

Possible solutions are:

  • Zoom tolerance window P-AXIS-00351 for filters
  • Reduce order P-AXIS-00140 of the filter
  • Reduce the reciprocal bandwidth P-AXIS-00080 of band-pass or band-stop filters
  • Choose a different filter prototype P-AXIS-00153
  • Increase the ratio of cut-off frequency to sample rate

Response

Class

6

Filter is temporarily deactivated and reactivated after reset

Solution

Class

7

Change filter parameters or increase tolerance window

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Error value

True, if axis filters have reached position window

%3:

Current value [0.1 µm or 0.0001°]

Unfiltered command value

%4:

Current value [0.1 µm or 0.0001°]

Filtered command value

%5:

Upper limit value [0.1 µm or 0.0001°]

Tolerance window P-AXIS-00351 for axis filter

Error type

-